Manufacturer Company

- Descriptions
STRIKE MX4 Parking Fast Pass System Control Panel
The HGS access control panel manages 4 long-range UHF HGS antennas at the parking entrance and exit points. It implements Global Anti-Passback by denying entry to vehicles that have not exited the parking lot. Permissions for parking entry and exit can be assigned to each vehicle individually or grouped vehicles can be assigned permissions under a group. The STRIKE MX4 HGS parking access control panel operates offline without needing to be connected to a computer, and transfers stored data to a computer via the HGS parking software to generate entry-exit logs and reports.
The HGS system parking control panel communicates via network with computers and other HGS control panels. Up to 510 parking entrance or exit points can be controlled by connecting HGS system panels on the same network. Featuring large memory and high query capacity, the Parking HGS recognition panel can simultaneously control entry and exit of up to 16,000 vehicles.
Technical Specifications of the 4-Channel Panel
-
Power Supply: 12-24V DC Max. 250mA (reverse connection does not damage the device)
-
100 Mb Ethernet Connection
-
4 Wiegand Ports (26, 34-bit auto detection – D0,D1 direct-reverse connection auto detection – broken data line detection – visual warning)
-
4 Relays (10A - for readers)
-
1 Relay (10A - for bell and alarms)
-
Card Digit Number: 2-4 Hex. (5-10 digits) Selectable
-
Adjustable Same Card Read Time (Global)
-
Log Capacity: 131,000 Records (recoverable after deletion)
-
Access Group Definition
-
Panel Selection per Access Group
-
5 Time Intervals
-
Access Count for Each Time Interval
-
Selection of Allowed Readers
-
Anti-Passback
-
Date Range and General Credit Assignment per Card
-
For Each Panel:
-
5 Working Time Intervals
-
Ability to Keep 3 Relays On/Off Outside Working Hours
-
Sending Auxiliary Messages to Panel Settings and Operator Programs via UTP
-
Relay Time Adjustment
-
Option for Credit Deduction on Entry Only
-
Capacity Control
-
Bell Ringing (second/minute selectable)
-
Automatic Opening of All Doors on Alarm
-
-
For Readers:
-
Relay Selection
-
Direction Determination
-
-
2 Inputs or 1 Input-1 Output Signal per Reader (Button, Sensor, Loop, Alarm, Output, Open-Close)
-
SQL Based Control and Reporting Software
-
Online Operation - Access Monitoring Screen
-
Visual Warning + Alarm Relay on Door Forced Entry
-
Data Backup as txt
-
Export Reports to Excel, Print Output


![]() | ||
File Name | Links | |